Product features
Xd5e series Ethernet PLC, including 30 and 60 point specifications.
Compatible with all functions of xd5 and supporting Ethernet communication
It is 12 times faster than XC series and has more internal resource space
Input type: NPN
Output type: Transistor (T)
Power specification: AC220V
Support x-net fieldbus function
Support high-speed counting (up to 80kHz), 4 ~ 10 axis pulse output (up to 100kHz), frequency measurement and other special functions
Support 1 ~ 16 expansion modules, 1 expansion ed and 1 ~ 2 expansion BD
Model List
Model | Input points(DC24V) | Output points (R,T) |
AC power supply | DCpower supply |
| Relay output | Transistor output | Transistor relay hybrid output | Relay output | Transistor output | Transistor relay hybrid output |
NPN | - | XD5E-30T4-E | - | - | - | - | 16 points | 14points |
- | XD5E-60T6-E | - | - | - | - | 36 points | 24 points |
- | XD5E-60T10-E | - | - | - | - | 36 points | 24 points |
Note: PNP PLC is a customized machine.
Basic specifications
Project | Specifications |
Insulation voltage | DC 500V above 2m Ω |
Anti noise | Noise voltage 1000vp-p# 1US pulse for 1 minute |
air | No corrosive and combustible gas |
ambient temperature | 0℃~60℃ |
ambient humidity | 5% ~ 95% (no condensation) |
USB port | USB quick download port, connected to PC for download / upload / monitoring |
Port1 port | RS232, connecting the upper computer, man-machine interface programming or debugging |
Port2 port | RS485 / RS232, connecting intelligent instrument, frequency converter, etc |
Ethernet port | RJ45, which connects the upper computer and monitoring, and communicates with other devices in the LAN |
install | It can be fixed with M3 screws or directly installed on the guide rail |
Grounding (FG) | The third kind of grounding (not common grounding with strong current system) |
Note: xd5e-60 point model has no USB port.
Performance specifications
Project | Specifications |
Program execution mode | Cyclic scanning mode |
Programming mode | Instruction and ladder diagram |
Processing speed | 0.03us |
Outage hold | Use flashrom and lithium battery (3V button battery) |
User program capacity ※ 1 | 1MB |
I/O Points ※2 | Total points | 30points | 60points |
Input points | 16pointsX0~X17 | 36points X0~X43 |
Output points | 14pointsY0~Y15 | 24points Y0~Y27 |
Internal coil(X)※3 | 1280points:X0~X77、X10000~X11777、X20000~X20177、X30000~X30077 |
Internal coil(Y)※4 | 1280points:Y0~Y77、Y10000~Y11777、Y20000~Y20177、Y30000~Y30077 |
Internal coil(M、HM) | 87000points | M0~M69999【HM0~HM11999】 |
Special use※6 SM0~SM4999 |
Technological process(S) | 9000points | S0~S7999【HS0~HS999】 |
Timer(T) | points | 7000points | T0~T4999【HT0~HT1999】 |
Specifications | 100ms timer: setting time: 0.1 ~ 3276.7 seconds 10ms timer: setting time: 0.01 ~ 327.67 seconds 1ms timer: setting time: 0.001 ~ 32.767 seconds |
Counter(C) | points | 7000points | C0~C4999【HC0~HC1999】 |
Specifications | 16 bit counter: setting value K0 ~ 32767 32-bit counter: set value - 2147483648 ~ + 2147483647 |
Data register(D) | 100000 words | D0~D69999【HD0~HD24999】 |
Special use※6 SD0~SD4999 |
FlashROM Register (FD) | 14192 words | FD0~FD8191 |
Special use※6 SFD0~SFD5999 |
High speed processing function | High speed counting, pulse output, external interrupt |
Password protection | 6-bit length ASCII |
Self diagnosis function | Power on self-test, monitoring timer, syntax check |
Notes:
※ 1: user program capacity refers to the maximum program capacity during confidential download.
※ 2: I / opoints refers to the number of terminals that users can access and output signals from the outside.
※ 3: X refers to the internal input relay. X exceeding the number of ipoints can be used as an intermediate relay.
※ 4: y refers to the internal output relay. Y exceeding the number of opoints can be used as an intermediate relay.
※ 5: [] flag, which is the default power-off holding area and cannot be changed.
※ 6: special use refers to the register of special use occupied by the system, which can not be used for other purposes. See Appendix 1 for details.
※ 7: the numbers of input coils and output relays / transistors are octal numbers, and the numbers of other memories are decimal numbers.
※ 8: I / O without real connection with peripheral equipment can be used as fast internal relay.
Function configuration table
× Not supported √ supported
Series and point | USB port | 232 port | 485 port | ether Network port | extend modular | extend BD board | Left extended ed module | High speed counting Number of routes | Pulse transmission Number of outlets (T / RT type) | external interrupt |
Increasing pattern | AB phase |
XD5E-30T4 | 1 | 1 | √ | 1 | 16 | 1 | 1 | 4 | 4 | 4 | 10 |
XD5E-60T6 | × | 1 | √ | 2 | 16 | 2 | 1 | 6 | 6 | 6 | 10 |
XD5E-60T10 | × | 1 | √ | 2 | 16 | 2 | 1 | 10 | 10 | 10 | 10 |
Note: all models are equipped with clock function as standard.
Appearance dimension drawing (unit: mm)
XD5E-30T4:
XD5E-60T6、XD5E-60T10: